How to Evaluate the Integrity of Intravenous Packages

How to Evaluate the Integrity of Intravenous Packages

It is critical that medical fluid bags and valves do not leak. IV bags, blood bags, and drainage collection bags are all examples of medical fluid bags. IV bags contain electrolytes and medications that flow from the bag into the patient's vein via a tube and a needle to provide them with life-sustaining fluids. The Food and Drug Administration (FDA) and the United States Pharmacopeia (USP) have established strict guidelines for testing container closure systems in order to ensure the safety of sterile products like IV bags. Testing these bags for leaks is critical because leaks can risk the overall sterility of the container and thus user safety.

IV Bags Testing using VeriPac 455 Series

VeriPac Vacuum Decay technology is regarded as a highly effective method for evaluating the integrity of liquid filled IV bags. This technology is recommended by UPS 1207 and is an FDA (Food and Drug Administration) consensus standard for Container Closure Integrity testing (CCIT) of high-risk package applications with fast, repeatable and reliable test results that provide quantitative and deterministic quality assurance. Being a non-destructive technique, Vacuum Decay offers a greater understanding of the packages and reduces waste. Irrespective of the defect location, this technology system can pick up both large and small defects. Additionally, PTI VeriPac system ensures leak detection and eliminates false positives by providing quantitative test data.

IV bags can be evaluated effectively using VeriPac 455 leak detection system. It is a non-destructive, non-invasive method that requires no sample preparation. Apart from package integrity testing, VeriPac 455 can be used for stability studies, clinical trial studies, quality assurance testing and production statistical process control (SPC).

Technology Overview

Under this method, a test chamber that is specifically designed to hold the package being evaluated is connected to the VeriPac 455 leak tester. The package is placed inside the test chamber to which vacuum is applied. The test chamber is observed for both vacuum level and change during a defined test time using the dual transducer technology. The presence of leaks and defects within the package is identified by monitoring changes in absolute and differential vacuum. VeriPac 455 series is designed for manual or automatic operation, and it is suitable for laboratory offline testing and QA/QC statistical process control.

Benefits of VeriPac 455 Series

  • Non-destructive, non-subjective, no sample preparation
  • Defect detection down to 0.01 cc/min
  • Highest level of sensitivity, repeatability and accuracy
  • Results proven superior to dye ingress
  • Deterministic, quantitative test method
  • Supports sustainable packaging and zero waste initiatives
  • ASTM test method and FDA standard
Readmore...
iv bags integrity testing, intravenous package testing, package integrity testing, veripac vacuum decay technology, cci testing of iv bags, ccit
687

Popular Blogs

Tags

How to Leak Test High Risk Medical Device Packages

Jan 25, 2022   |   7791

Medical device leak testing is considered a critical step in ensuring package integrity primarily due to its sensitive nature. Leaks in the device can cause serious health risks to the patients and result in huge financial losses to the manufacturer. PTI's Seal-Scan technology is a non-destructive seal quality inspection technique for high risk pharmaceuticals and medical devices.

CCI Inspection of Vials with Helium Leak Detection Technology

Jul 12, 2023   |   4643

Helium leak detection technology has revolutionized container closure integrity testing in the pharmaceutical industry by providing highly sensitive and precise detection of leaks in vials. By utilizing the unique properties of helium gas, this method enhances the overall integrity of vial packaging, ensuring the safety and quality of pharmaceutical products.

Container Closure Integrity Testing (CCIT) - An Ideal Solution for the Pharmaceutical Industry

Sep 01, 2020   |   4371

Container Closure Integrity Testing is a method of leak detection using a non-destructive packaging inspection system to prevent possible contamination in pharmaceutical products.

Understanding Pressure Decay Leak Testing

Jun 07, 2021   |   3598

Pressure Decay leak test is a sensitive leak detection method particulary for testing small leaks. It is applicable across multiple industries like pharmaceutical, medical device and food and nutrition industries.
ptiusa

Our technologies conform to ASTM and other regulatory standards.

Packaging Technologies & Inspection

PTI offers inspection systems for package leak testing, seal integrity and container closure integrity testing (CCIT). Our technologies exclude subjectivity from package testing, and use test methods that conform to ASTM standards. PTI's inspection technologies are deterministic test methods that produce quantitative test result data. We specialize in offering the entire solution including test method development and equipment validation.

Sales Channel Partner Portal Login

Get in Touch

 

Packaging Technologies & Inspection

PTI offers inspection systems for package leak testing, seal integrity and container closure integrity testing (CCIT). Our technologies exclude subjectivity from package testing, and use test methods that conform to ASTM standards. PTI's inspection technologies are deterministic test methods that produce quantitative test result data. We specialize in offering the entire solution including test method development and equipment validation.

Sales Channel Partner Portal Login

ptiusa

Our technologies conform to ASTM and other regulatory standards.

Get in Touch

 
Popup