Package Integrity Testing using VeriPac Series Products and Solutions

Package Integrity Testing using VeriPac Series Products and Solutions

There are certain aspects that need to be maintained regardless of whether you operate in the food packaging sector or the pharmaceutical products manufacturing industry to ensure that a quality product will be provided to the clients. Package integrity testing is required for items that must be packaged so that they can be sterilized and maintained sterile for a defined amount of time, throughout the product lifecycle.

Package Integrity Testing Using VeriPac 455

The VeriPac 455 is a non-destructive, non-invasive, and highly sensitive Container Closure Integrity Testing (CCIT) method that may be implemented into protocols at any stage of the handling process. Stability research, clinical trial investigations, quality assurance testing, and production statistical process control are examples of applications for this technology (SPC). Leak rates as low as 0.05 cc/min can be found with the VeriPac 455. Results have consistently outperformed and outperformed the dye ingress test in terms of accuracy.

The VeriPac 455 core technology is based on the ASTM vacuum decay leak test method (F2338-09) recognized by the FDA as a consensus standard for package integrity testing. This test method was developed using VeriPac leak test instruments. The VeriPac 455 is equipped with the patented PERMA-Vac dual vacuum transducer technology, which increases test sensitivity and yields reproducible, dependable results.

Additionally, the VeriPac 455 contains major improvements in networking and internet access that enable remote operation, system monitoring, and MES integration. Test systems can be built to operate automatically or manually. This inspection method is appropriate for QA/QC statistical process control and laboratory offline testing. The test cycle only lasts a few seconds, the results are objective, and the testing is non-destructive to the product and the package.

Inspection Criteria

  • Measures seal integrity of entire container or package
  • Measures and verifies container closure system integrity
  • Tests for gas leaks for dry products (lyophilized vials, powder filled)
  • Tests for liquid leaks (liquid filled vials, pre-filled syringes)

Benefits

  • Non-destructive, non-subjective, no sample preparation
  • Defect detection down to 0.01 cc/min
  • Highest level of sensitivity, repeatability and accuracy
  • Results proven superior to dye ingress
  • Deterministic, quantitative test method
  • Supports sustainable packaging and zero waste initiatives
  • ASTM test method F2338 and FDA standard for package integrity testing
  • Vacuum Decay technology referenced in USP 1207 guidelines
Readmore...
package integrity testing, veripac 455, ccit, vacuum decay, package quality inspection
1406
30
Mar 2021

Vacuum Decay Technology for Ophthalmic Product Package Inspection

Vacuum Decay Technology for Ophthalmic Product Package Inspection

Ophthalmic preparations majorly consist of sterile liquid, semi-solid or solid preparations with active pharmaceutical ingredients. More than 70% of ophthalmic drug products are supplied in plastic container closure systems, which generally contain a month or longer supply of the drug. The liquid filled package formats are often soft containers with snap on or torque screw caps, but also include foil lidded blister packs for single use contacts. Any breach, channel, or micro leak in the container closure systems can greatly increase the risk of contamination of the ophthalmic solution. Therefore, in terms of product performance and safety, ophthalmic drug product packaging is considered to be more crucial than the packaging used for solid oral drug dosage forms.

Packaging defects are the key factors contributing to contaminated eye care solutions. For instance, the soft plastic containers and snap caps are typically blow molded plastics. The area for primary concern with both torque and snap on caps is the flange area of the bottle. Although traditional methods like visual inspection can detect many container failure modes of an uncapped container, inaccuracies or marks in the flange area can go unnoticed. However, such a defect can provide a clear path for bacteria and fungi to transfer into the product. This is both the most common and most difficult container defect to detect and remains hidden beneath the cap once it is applied. Hence, manufacturers require leak detection techniques capable of detecting even minute leaks for ensuring highly sensitive leak testing solutions.

PTI’s Vacuum Decay technology is a non-destructive leak testing method, capable of evaluating both liquid and air-filled containers and detecting defects as small as below 1 micron. Proven to be the most practical and sensitive vacuum-based leak test method, Vacuum Decay technology is an ASTM test method, FDA consensus standard, eliminating false positives and subjective results associated with manual visual inspection. Vacuum Decay technology is capable of identifying leaks in sealed rigid, semi-rigid and flexible packaging made of non-porous or porous materials. It provides reliable, accurate and repeatable test results that ensure deterministic package testing and leak detection.

PTI’s VeriPac 455 is a deterministic and quantitative package inspection solution for highly sensitive liquid filled containers making it ideal for ophthalmic package leak testing needs. This test method was developed using VeriPac leak test instruments. The VeriPac 455 features patented dual vacuum transducer technology, PERMA-Vac, which offers increased test sensitivity and produces repeatable, reliable results. Under this technique, the VeriPac 455 leak tester is connected to a test chamber that contains sample packages. Vacuum is applied to these packages and a dual transducer technology is used to monitor the test chamber for both the level of vacuum as well as the change in vacuum over a predetermined test time. The changes in absolute and differential vacuum indicate the presence of leaks and defects within the package. The test cycle takes only a few seconds, results are non-subjective, and testing is non-destructive to both product and package.

Benefits of Vacuum Decay technology

  • Non-destructive, non-subjective, no sample preparation
  • Defect detection down to 0.01 cc/min
  • Results have proven superior to dye ingress
  • Deterministic, quantitative test method
  • Supports sustainable packaging and zero waste initiatives
  • ASTM test method and FDA standard
Readmore...
vacuum decay technology, veripac 455, ophthalmic product package inspection, package inspection technology
2453

Popular Blogs

Tags

How to Leak Test High Risk Medical Device Packages

Jan 25, 2022   |   7817

Medical device leak testing is considered a critical step in ensuring package integrity primarily due to its sensitive nature. Leaks in the device can cause serious health risks to the patients and result in huge financial losses to the manufacturer. PTI's Seal-Scan technology is a non-destructive seal quality inspection technique for high risk pharmaceuticals and medical devices.

CCI Inspection of Vials with Helium Leak Detection Technology

Jul 12, 2023   |   4669

Helium leak detection technology has revolutionized container closure integrity testing in the pharmaceutical industry by providing highly sensitive and precise detection of leaks in vials. By utilizing the unique properties of helium gas, this method enhances the overall integrity of vial packaging, ensuring the safety and quality of pharmaceutical products.

Container Closure Integrity Testing (CCIT) - An Ideal Solution for the Pharmaceutical Industry

Sep 01, 2020   |   4414

Container Closure Integrity Testing is a method of leak detection using a non-destructive packaging inspection system to prevent possible contamination in pharmaceutical products.

Understanding Pressure Decay Leak Testing

Jun 07, 2021   |   3637

Pressure Decay leak test is a sensitive leak detection method particulary for testing small leaks. It is applicable across multiple industries like pharmaceutical, medical device and food and nutrition industries.
ptiusa

Our technologies conform to ASTM and other regulatory standards.

Packaging Technologies & Inspection

PTI offers inspection systems for package leak testing, seal integrity and container closure integrity testing (CCIT). Our technologies exclude subjectivity from package testing, and use test methods that conform to ASTM standards. PTI's inspection technologies are deterministic test methods that produce quantitative test result data. We specialize in offering the entire solution including test method development and equipment validation.

Sales Channel Partner Portal Login

Get in Touch

 

Packaging Technologies & Inspection

PTI offers inspection systems for package leak testing, seal integrity and container closure integrity testing (CCIT). Our technologies exclude subjectivity from package testing, and use test methods that conform to ASTM standards. PTI's inspection technologies are deterministic test methods that produce quantitative test result data. We specialize in offering the entire solution including test method development and equipment validation.

Sales Channel Partner Portal Login

ptiusa

Our technologies conform to ASTM and other regulatory standards.

Get in Touch

 
Popup